Skip to content

nad

How is NAD+ measured in research?

Research overview 7 min read

On this page
  1. What exactly is being measured?
  2. How is NAD+ measured?
  3. Why do whole blood, plasma and tissue give different numbers?
  4. Why must samples be handled quickly?
  5. Why do reported NAD+ levels differ between studies?
  6. Sources

Researchers measure NAD+, a coenzyme cells use in chemical reactions [G1], by extracting it from cells, tissue or blood and reading it with an enzymatic assay [G2], liquid chromatography or mass spectrometry [G1, G2]. A coenzyme is a helper molecule that some enzymes need to work. Reported levels differ partly because NAD+ can break down quickly once a sample is taken [G4, G5], and because whole blood, plasma and tissue hold very different amounts [G5, G9]. A 2021 review, while noting that biological variability "may indeed play a role", judged it "more likely that analytical variation represents a major contributory factor" to differences between reported values in this field [G2].

What exactly is being measured?

In some chemical reactions, NAD+ picks up electrons and hydrogen and becomes NADH [G1]. Reactions in which electrons move between molecules are called redox reactions. NAD+ is the oxidised form and NADH the reduced form [G1].

Some studies report the ratio between the two forms [G3, G8]. Others measure a whole panel of related molecules, sometimes called the NAD+ metabolome, in one analysis [G5]. Trammell and Brenner argued that, because each of these metabolites can be converted into others, a snapshot of one alone "has the potential to be misleading" [G1].

Units depend on the sample. Mouse tissue values have been given per gram of tissue, and mouse blood per millilitre [G9].

How is NAD+ measured?

Enzymatic cycling and colorimetric assays. Brunnbauer et al. built an assay for NAD+ in human plasma around a two-step enzymatic cycling reaction, read by a change in colour [G6]. In a cycling reaction, enzymes use up and remake the measured molecule over and over, so the coloured product builds up. The assay's sensitivity ran "from the low micromolar into the low nanomolar domain" [G6]. A micromolar (µM) is a millionth of a mole per litre; a nanomolar (nM) is a thousand times smaller. Guo et al. called colorimetric assays, in which a probe forms a coloured product, "the most widely used" [G8]. They noted that each run needs a standard curve, a set of known amounts measured alongside the samples, and that the dynamic range, the span of amounts a method can read, is narrower than with LC/MS [G8]. Braidy et al. added that commonly available biochemical assays "provide indirect measurements" [G2].

HPLC with UV detection. High-performance liquid chromatography (HPLC) separates molecules by how long they take to pass through a column, their retention time; a UV detector then reads each one by the ultraviolet light it absorbs. Mori et al. used this approach on mouse tissues and blood [G9]. Trammell and Brenner wrote that it "does not offer the specificity and sensitivity necessary for robust quantification of complex samples", because one peak can hold other molecules with the same retention time [G1].

LC-MS/MS. Mass spectrometry sorts molecules by their mass-to-charge ratio, and adding it to liquid chromatography increases specificity [G1]. One complication is ionisation suppression, other molecules in the sample weakening the signal [G1]. Trammell and Brenner's answer was isotope-labelled internal standards, versions of the molecules made with heavier carbon that are suppressed to the same degree [G1]. Guo et al. raised a second complication, stating that NAD+/NADH "cannot be reliably calculated from the relative intensities of mass spectrometry signals alone", because the two forms ionise with different efficiencies [G8].

Method How it reads NAD+ Sample types in these sources Limits the sources note
Enzymatic cycling (colorimetric) Colour from a repeating enzyme reaction [G6] Human plasma [G6] Indirect; narrower dynamic range; standard curve each run [G2, G8]
HPLC-UV Separation, then UV absorbance [G9] Mouse tissues and blood [G9] One peak may hold several molecules [G1]
LC-MS/MS Separation, then mass [G1] Cells, tissue, whole blood, plasma, CSF [G4, G5] Signal suppression; needs internal standards and calibration [G1, G8]

Why do whole blood, plasma and tissue give different numbers?

Whole blood still contains its cells. Plasma is the liquid left when the cells are removed from blood kept from clotting; serum is the liquid left after blood clots.

In mice, Mori et al. found NAD levels that "generally ranged between 200 and 900 nmol/g" of tissue, while blood held about 40 nmol per millilitre [G9].

In plasma, serum and whole blood from the same blood draw of nine volunteers, Giner et al. found NAD+, NADH, NADP+ and NADPH only in whole blood; in plasma and serum they were undetectable [G5]. The authors took this to confirm that these molecules come from the cells in blood, and noted that whole blood is about 45% red blood cells [G5].

A method's detection limit is the smallest amount it can pick up. Demarest et al. found NAD+ in plasma above their LC-MS/MS method's detection limit, with NADH at or below it [G4]. Brunnbauer et al.'s cycling assay, built for plasma, measured NAD+ in frozen human plasma [G6].

Why must samples be handled quickly?

Demarest et al. left samples at room temperature before extraction [G4]. In cultured human cells, NAD+ was "only stable at room temperature for 10 min, with greater than 80% decrease within 30 min", and NADH also fell rapidly [G4]. Nicotinamide rose later, consistent with breakdown [G4]. Human red blood cells and monkey skeletal muscle behaved similarly [G4].

In whole blood, Giner et al. reported that "NAD+ degrades to Nam", meaning nicotinamide [G5]. A freeze–thaw cycle means thawing a frozen sample and freezing it again. After the second one, less than 20% of NAD+ and NADH together remained [G5].

NAD+ and NADH can also turn into each other during extraction, the step that pulls the molecules out of cells or tissue [G3]. Comparing seven solvents on cultured cells and mouse tissues, Lu et al. found that a formic-acid version of an acetonitrile–methanol–water mix gave "the least interconversion" [G3]. They wrote that samples "should be neutralized immediately after extraction to avoid acid-catalyzed degradation" [G3]. Braidy et al. wrote that "quick quenching of metabolism is essential", quenching meaning a fast stop to the chemistry in the sample [G2]. Trammell and Brenner called extraction methods that do not inactivate enzymes when cells are broken open "clearly flawed" [G1].

In Giner et al.'s study, whole blood was snap-frozen in liquid nitrogen after collection, meaning frozen almost instantly [G5]. Mori et al. also snap-froze mouse tissues and blood in liquid nitrogen, then extracted them in perchloric acid [G9]. One whole-blood assay, used on blood from 50 people, acidified the blood with perchloric acid during collection [G7].

Why do reported NAD+ levels differ between studies?

Giner et al. attributed differences between studies to "different (or even uncharacterized) conditions" in blood collection, analytical procedures and the people sampled, among other factors [G5]. Demarest et al. wrote that sample processing, normalisation (what a value is divided by, such as tissue weight) and measurement strategies can alter the values obtained [G4].

A 2026 study reported 1,340 whole-blood NAD measurements from 1,068 adults [G10].

For what NAD+ itself has been studied for, see the research overview for NAD+.


All products are sold for laboratory research use only. Not for human or veterinary use. Nothing on this page is medical advice.

Sources

Keep reading